{"id":5397243723937,"title":"Victron BatteryProtect BP-65 - 65AMP - 6-35 VDC [BPR000065400]","handle":"victron-batteryprotect-bp-65-65amp-6-35-vdc-bpr000065400","description":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBatteryProtect BP-65 - 65AMP - 6-35 VDC\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. \u003c\/li\u003e\n\u003cli\u003e12\/24V auto ranging The BatteryProtect automatically detects system voltage \u003c\/li\u003e\n\u003cli\u003eProgramming made easy The BatteryProtect can be set to engage \/ disengage at several different voltages. The seven segment display will indicate which setting has been chosen. \u003c\/li\u003e\n\u003cli\u003eA special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. \u003c\/li\u003e\n\u003cli\u003eUltra low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. \u003c\/li\u003e\n\u003cli\u003eOver voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.\u003c\/li\u003e\n\u003cli\u003eIgnition proof No relays but MOSFET switches, and therefore no sparks.\u003c\/li\u003e\n\u003cli\u003eDelayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/20150209_Warranty_final_en.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eWarranty Info\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:mm9mlp1p ---\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82905QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cstyle\u003e.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }\u003c\/style\u003e\u003cdiv class=\"embed-container\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/mg0kwJIo-5U\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e","published_at":"2020-07-16T13:46:58-05:00","created_at":"2020-07-16T13:46:58-05:00","vendor":"Victron Energy","type":"Battery Management","tags":["1st Class Eligible","Brand_Victron Energy","Electrical","Electrical | Battery Management"],"price":3995,"price_min":3995,"price_max":11645,"available":true,"price_varies":true,"compare_at_price":4700,"compare_at_price_min":4700,"compare_at_price_max":13700,"compare_at_price_varies":true,"variants":[{"id":35272773370017,"title":"65AMP","option1":"65AMP","option2":null,"option3":null,"sku":"CWR-82905","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Victron BatteryProtect BP-65 - 65AMP - 6-35 VDC [BPR000065400] - 65AMP","public_title":"65AMP","options":["65AMP"],"price":3995,"weight":227,"compare_at_price":4700,"inventory_management":"cwr-distribution","barcode":"8719076034193","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":35272773402785,"title":"100AMP","option1":"100AMP","option2":null,"option3":null,"sku":"CWR-82907","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Victron BatteryProtect BP-65 - 65AMP - 6-35 VDC [BPR000065400] - 100AMP","public_title":"100AMP","options":["100AMP"],"price":5865,"weight":499,"compare_at_price":6900,"inventory_management":"cwr-distribution","barcode":"8719076021438","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":35272773435553,"title":"220AMP","option1":"220AMP","option2":null,"option3":null,"sku":"CWR-82915","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Victron BatteryProtect BP-65 - 65AMP - 6-35 VDC [BPR000065400] - 220AMP","public_title":"220AMP","options":["220AMP"],"price":11645,"weight":1134,"compare_at_price":13700,"inventory_management":"cwr-distribution","barcode":"8719076021452","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0325\/9134\/7771\/products\/82905XL.jpg?v=1614562099"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0325\/9134\/7771\/products\/82905XL.jpg?v=1614562099","options":["Size"],"media":[{"alt":"Victron BatteryProtect BP-65 - 65AMP - 6-35 VDC [BPR000065400] | One Stop Overland ","id":10109510385825,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0325\/9134\/7771\/products\/82905XL.jpg?v=1594925221"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/0325\/9134\/7771\/products\/82905XL.jpg?v=1594925221","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":" \u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBatteryProtect BP-65 - 65AMP - 6-35 VDC\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. \u003c\/li\u003e\n\u003cli\u003e12\/24V auto ranging The BatteryProtect automatically detects system voltage \u003c\/li\u003e\n\u003cli\u003eProgramming made easy The BatteryProtect can be set to engage \/ disengage at several different voltages. The seven segment display will indicate which setting has been chosen. \u003c\/li\u003e\n\u003cli\u003eA special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. \u003c\/li\u003e\n\u003cli\u003eUltra low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. \u003c\/li\u003e\n\u003cli\u003eOver voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.\u003c\/li\u003e\n\u003cli\u003eIgnition proof No relays but MOSFET switches, and therefore no sparks.\u003c\/li\u003e\n\u003cli\u003eDelayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/20150209_Warranty_final_en.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eWarranty Info\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:mm9mlp1p ---\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82905QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cstyle\u003e.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }\u003c\/style\u003e\u003cdiv class=\"embed-container\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/mg0kwJIo-5U\" frameborder=\"0\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e"}

Victron BatteryProtect BP-65 - 65AMP - 6-35 VDC [BPR000065400]

Product Description

BatteryProtect BP-65 - 65AMP - 6-35 VDC

Features:

  • The BatteryProtect disconnects the battery from non essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine. 
  • 12/24V auto ranging The BatteryProtect automatically detects system voltage 
  • Programming made easy The BatteryProtect can be set to engage / disengage at several different voltages. The seven segment display will indicate which setting has been chosen. 
  • A special setting for Li-ion batteries In this mode the BatteryProtect can be controlled by the VE.Bus BMS. Note: the BatteryProtect can also be used as a charge interrupter in between a battery charger and a Li-ion battery. See connection diagram in the manual. 
  • Ultra low current consumption This is important in case of Li-ion batteries, especially after low voltage shutdown. Please see our Li-ion battery datasheet and the VE.Bus BMS manual for more information. 
  • Over voltage protection To prevent damage to sensitive loads due to over voltage, the load is disconnected whenever the DC voltage exceeds 16V respectively 32V.
  • Ignition proof No relays but MOSFET switches, and therefore no sparks.
  • Delayed alarm output The alarm output is activated if the battery voltage drops below the preset disconnect level during more than 12 seconds. Starting the engine will therefore not activate the alarm. The alarm output is a short circuit proof open collector output to the negative (minus) rail, max. current 50 mA. The alarm output is typically used to activate a buzzer, LED or relay. Delayed load disconnect and delayed reconnect The load will be disconnected 90 seconds after the alarm has been activated. If the battery voltage increases again to the connect threshold within this time period (after the engine has been started for example), the load will not be disconnected. The load will be reconnected 30 seconds after the battery voltage has increased to more than the preset reconnect voltage.

Warranty Info

WarningWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.

Please contact your dealer for any returns, repairs or support issues related to this product.